Skip to main content

Table 2 Details of primers used in the development of triplex NALFIA

From: Novel triplex nucleic acid lateral flow immunoassay for rapid detection of Nipah virus, Middle East respiratory syndrome coronavirus and Reston ebolavirus

Virus

Target gene

Primer

Amplicon length (bp)

Ta

Reference

Sequence 5’-3’

Length

NiV

N

F

TCAGCAGGAAGGCAAGAGAGTAA

23

100

60 °C

Mungall et al. 2006

R

CCCCTTCATCGATATCTTGATCA

23

REBOV

Vp40

F

CTATGGTTATCACCCAGGATTGTG

24

80

60 °C

Trombley et al. 2010

R

GTAACTATCCTGCTTGTCCATGTG

24

MERS-CoV

UpE

F

GCAACGCGCGATTCAGTT

18

92

58 °C

Corman et al. 2012

R

GCCTCTACACGGGACCCATA

20